Available now
- CSV upload and file validation
- Limb symmetry index (LSI)
- Inter-limb difference
- Hamstring-to-quadriceps (H:Q) ratio
- Batch quality control summary
- HTML report and CSV outputs
OrthoWave helps sports medicine and rehabilitation teams process isokinetic test data, identify quality issues, calculate strength symmetry metrics, and prepare standardized reports through a repeatable analytical workflow.
OrthoWave supports clinician review. It does not independently make return-to-sport or treatment decisions.
Teams often spend more effort wrangling exports and rebuilding spreadsheets than reviewing results. OrthoWave replaces that manual step with a repeatable process.
Symmetry metrics rebuilt by hand in spreadsheets after each test: slow, error-prone, and hard to reproduce between people.
Involved and uninvolved limbs recorded differently across sessions and testers, which makes comparisons unreliable.
Exports arrive in varying layouts and need cleanup before anything is usable.
Missing pairs, duplicate entries, or impossible values caught by eye, if at all.
A readable summary is assembled manually, delaying review with the athlete and referring clinicians.
Results spread across spreadsheets and machines with no consistent format.
Reads isokinetic strength test data from a CSV file in a defined format, including multiple subjects and test speeds.
Validates the file before analysis and reports what was found, so problems are visible instead of silently absorbed.
Computes limb symmetry index, inter-limb difference, and hamstring-to-quadriceps ratio using documented formulas.
Generates an HTML report and downloadable CSV tables in the same layout every time, for clinician review.
The application guides each analysis through the same sequence, so every assessment is handled consistently.
Provide isokinetic strength test data in the supported CSV format.
The file is checked for required columns, limb and movement pairs, duplicates, and values that cannot be analyzed.
Limb symmetry index, inter-limb difference, and hamstring-to-quadriceps ratio are computed for each assessment.
Open the HTML report and download the CSV outputs and batch quality summary for clinician review.
Every metric uses a stated formula, and every file passes the same checks before results are produced.
LSI = 100 × involved ÷ uninvolvedExpressed as a percentage of the uninvolved limb.
Difference = uninvolved − involvedAn absolute difference, in the same units as the input values.
H:Q = 100 × flexion ÷ extensionExpressed as a percentage, calculated from flexion and extension values.
A standardized summary and downloadable tables, laid out the same way for every assessment.
Illustrative recreation of the application's Results screen. Identifiers are examples; no patient data is shown.
| Metric | Involved | Uninvolved | LSI | Difference |
|---|---|---|---|---|
| Quadriceps (extension) peak torqueBelow the illustrative 90% reference line | 2.41 | 2.98 | 80.9% | 0.57 |
| Hamstring (flexion) peak torqueAt or above the illustrative 90% reference line | 1.52 | 1.60 | 95.0% | 0.08 |
OrthoWave reads a structured CSV file. Data exported from a dynamometer may need to be arranged into this layout first. If you are unsure whether your export fits, tell us what you have.
subject_idmovementangular_velocity_deg_slimb_statusmetric_namevaluegraft_typeUse de-identified data only. Files with columns that suggest personal identifiers are rejected.
We keep this page aligned with what the application actually does. Planned items are not available.
How OrthoWave's outputs fit research workflows, and what is not yet available.
Tell us about your testing workflow and we can arrange a demonstration or share an example report. Please do not send patient-identifiable data.